Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 40.889
Filtrar
1.
Ultrason Sonochem ; 105: 106858, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38564910

RESUMO

Zinc sulfide/graphitic Carbon Nitride binary nanosheets were synthesized by using a novel sonochemical pathway with high electrocatalytic ability. The as- obtained samples were characterized by various analytical methods such as Transmission Electron Microscopy (TEM), Field emission scanning electron microscopy (FESEM), Energy-dispersive X-ray spectroscopy (EDS), X-ray diffraction analysis (XRD), and X-ray photoelectron spectroscopy (XPS) to evaluate the properties of ZnS@CNS synthesized by this new route. Subsequently, the electrical and electrochemical performance of the proposed electrodes were characterized by using EIS and CV to establish an electroactive ability of the nanocomposites. The complete properties like structural and physical of ZnS@CNS were analyzed. As-prepared binary nanocomposite was applied towards the detection of anticancer drug (flutamide) by various electrochemical methods such as cyclic voltammetry (CV), differential pulse voltammetry (DPV) and amperometry. The glassy carbon electrode modified with a ZnS@CNS composite demonstrates a remarkable electrocatalytic efficiency for detecting flutamide in a pH 7.0 (PBS). The composite modified electrode shows synergistic effect of ZnS and CNS catalyst. The electrochemical sensing performance of the linear range was improved significantly due to high electroactive sites and rapid electron transport pathways. Crucially, the electrochemical method was successfully demonstrated in biological fluids which reveals its potential real-time applicability in the analysis of drug.


Assuntos
Antineoplásicos , Eletrodos , Grafite , Compostos de Nitrogênio , Sulfetos , Ondas Ultrassônicas , Compostos de Zinco , Compostos de Zinco/química , Sulfetos/química , Antineoplásicos/química , Grafite/química , Flutamida/análise , Flutamida/química , Técnicas Eletroquímicas/métodos , Técnicas de Química Sintética , Eletroquímica , Limite de Detecção , Catálise , Nanocompostos/química , Nanoestruturas/química
2.
Food Chem ; 448: 139210, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-38569408

RESUMO

The detection of heavy metals in tea infusions is important because of the potential health risks associated with their consumption. Existing highly sensitive detection methods pose challenges because they are complicated and time-consuming. In this study, we developed an innovative and simple method using Ag nanoparticles-modified resin (AgNPs-MR) for pre-enrichment prior to laser-induced breakdown spectroscopy for the simultaneous analysis of Cr (III), Cu (II), and Pb (II) in tea infusions. Signal enhancement using AgNPs-MR resulted in amplification with limits of detection of 0.22 µg L-1 for Cr (III), 0.33 µg L-1 for Cu (II), and 1.25 µg L-1 for Pb (II). Quantitative analyses of these ions in infusions of black tea from various brands yielded recoveries ranging from 83.3% to 114.5%. This method is effective as a direct and highly sensitive technique for precisely quantifying trace concentrations of heavy metals in tea infusions.


Assuntos
Cromo , Cobre , Contaminação de Alimentos , Chumbo , Nanopartículas Metálicas , Prata , Chá , Chá/química , Cromo/análise , Chumbo/análise , Prata/química , Nanopartículas Metálicas/química , Cobre/análise , Contaminação de Alimentos/análise , Análise Espectral/métodos , Lasers , Camellia sinensis/química , Metais Pesados/análise , Limite de Detecção
3.
Mikrochim Acta ; 191(5): 276, 2024 04 22.
Artigo em Inglês | MEDLINE | ID: mdl-38644435

RESUMO

Solid-phase microextraction (SPME) coupled with electrospray ionization mass spectrometry (ESI-MS) was developed for rapid and sensitive determination of endogenous androgens. The SPME probe is coated with covalent organic frameworks (COFs) synthesized by reacting 1,3,5-tri(4-aminophenyl)benzene (TPB) with 2,5-dioctyloxybenzaldehyde (C8PDA). This COFs-SPME probe offers several advantages, including enhanced extraction efficiency and stability. The analytical method exhibited wide linearity (0.1-100.0 µg L-1), low limits of detection (0.03-0.07 µg L-1), high enrichment factors (37-154), and satisfactory relative standard deviations (RSDs) for both within one probe (4.0-14.8%) and between different probes (3.4-12.7%). These remarkable performance characteristics highlight the reliability and precision of the COFs-SPME-ESI-MS method. The developed method was successfully applied to detect five kinds of endogenous androgens in female serum samples, indicating that the developed analytical method has great potential for application in preliminary clinical diagnosis.


Assuntos
Androgênios , Limite de Detecção , Microextração em Fase Sólida , Espectrometria de Massas por Ionização por Electrospray , Microextração em Fase Sólida/métodos , Espectrometria de Massas por Ionização por Electrospray/métodos , Humanos , Androgênios/sangue , Androgênios/análise , Androgênios/química , Feminino , Estruturas Metalorgânicas/química , Reprodutibilidade dos Testes
4.
Biosens Bioelectron ; 256: 116266, 2024 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-38636122

RESUMO

As a heavy metal pollutant, Cd2+ often enters the human body through the food chain causing great harm to human health. Whole-cell biosensor is an emerging technology for rapid on-site detection of heavy metals with the advantages of inexpensive, fast to mass-produce, and strong in anti-interference resistance, but suffering from insatisfactory specificity. In this study, a strategy of Adjacent Site Saturation Mutation (ASSM) was designed to improve the specificity of transcription factor CadR, which acted as the recognition element and determined the specificity of whole cell Cd2+ biosensors. A specific saturated library was constructed using the strategy of adjacent mutation. After two rounds of high-throughput visual screening, a whole-cell biosensor with good response to Cd2+, and with significant weakened Hg2+ interference was obtained. The optimized whole-cell biosensor showed a linear dynamic concentration range from 500 nM to 100 µM, a detection limit of 0.079 µM, and has satisfactory specificity and anti-interference. The ASSM strategy proposed in this study can provide a new method for the application of synthetic biology in food safety detection, indicating the importance of whole-cell biosensors for the detection of heavy metals.


Assuntos
Técnicas Biossensoriais , Cádmio , Mutação , Técnicas Biossensoriais/métodos , Cádmio/química , Humanos , Limite de Detecção , Fatores de Transcrição/genética , Ensaios de Triagem em Larga Escala/métodos
5.
ACS Sens ; 9(4): 2141-2148, 2024 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-38578241

RESUMO

The glycated hemoglobin (HbA1c) level, which is defined as the ratio of HbA1c to total hemoglobin (tHb, including glycated and unglycated hemoglobin), is considered one of the preferred indicators for diabetes monitoring. Generally, assessment of the HbA1c level requires separate determination of tHb and HbA1c concentrations after a complex separation step. This undoubtedly increases the cost of the assay, and the loss or degradation of HbA1c during the separation process results in a decrease in the accuracy of the assay. Therefore, this study explored a dual-signal acquisition method for the one-step simultaneous evaluation of tHb and HbA1c. Quantification of tHb: graphene adsorbed carbon quantum dots and methylene blue were utilized as the substrate material and linked to the antibody. tHb was captured on the substrate by the antibody. The unique heme group on tHb catalyzed the production of •OH from H2O2 to degrade methylene blue on the substrate, and a quantitative relationship between the tHb concentration and the methylene blue oxidation current signal was constructed. Quantification of HbA1c: complex labels with HbA1c recognition were made of ZIF-8-ferrocene-gold nanoparticles-mercaptophenylboronic acid. The specific recognition of the boronic acid bond with the unique cis-diol structure of HbA1c establishes a quantitative relationship between the oxidation current of the label-loaded ferrocene and the concentration of HbA1c. Thus, the HbA1c level can be assessed with only one signal readout. The sensor exhibited extensive detection ranges (0.200-600 ng/mL for tHb and 0.100-300 ng/mL for HbA1c) and low detection limits (4.00 × 10-3 ng/mL for tHb and 1.03 × 10-2 ng/mL for HbA1c).


Assuntos
Hemoglobinas Glicadas , Azul de Metileno , Hemoglobinas Glicadas/análise , Humanos , Azul de Metileno/química , Grafite/química , Ouro/química , Nanopartículas Metálicas/química , Pontos Quânticos/química , Hemoglobinas/análise , Hemoglobinas/química , Ácidos Borônicos/química , Compostos Ferrosos/química , Metalocenos/química , Limite de Detecção , Técnicas Eletroquímicas/métodos , Peróxido de Hidrogênio/química
6.
J Chromatogr A ; 1722: 464846, 2024 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-38579612

RESUMO

In forensic science, glyphosate (GLYP) and glufosinate (GLUF), a class of non-selective broad-spectrum herbicides, have been frequently encountered in many fatal poisoning and suicide cases due to their widespread availability. Therefore, it is essential to develop an effective method for detecting these compounds. Some conventional methods, such as gas chromatography-mass spectrometry (GC-MS) or liquid chromatography-mass spectrometry (LC-MS), have been reported to detect these compounds. However, these methods are not ideal for their time-consuming and non-sensitive feature. Herein, probe electrospray ionization (PESI) tandem mass spectrometry (MS/MS), a fast and sensitive technique, was applied for the determination of GLYP and GLUF in human blood, which can obtain analytical results within 0.5 min without derivatization and chromatographic separation. After protein precipitation of blood samples, the supernatant was mixed with isopropanol and ultra-pure water (1:1 v/v). Then, 8 µL of the mixture was introduced into the plastic sample plate for PESI-MS/MS analysis. The limits of detection (LODs) of the method were 0.50 µg/mL and 0.25 µg/mL for two analytes, and the limits of quantitation (LOQs) were both 1.00 µg/mL, which are higher than the concentration of reported poisoning and fatal cases. In the linear range of 1-500 µg/mL, the regression coefficients (r2) for GLYP and GLUF were over 0.99. The matrix effects ranged from 94.8 % to 119.5 %, and the biases were below 4.3 %. The recoveries ranged between 84.8 % and 107.4 %, and the biases were below 7.6 %. Meanwhile, the method was effectively utilized to detect and quantify the blood, urine, and other samples. Consequently, the results suggest that PESI-MS/MS is a straightforward, fast, and sensitive method for detecting GLUF and GLYP in forensics. In the future, PESI-MS/MS will become an indispensable technique for polar substances in grassroots units of public security where rapid detection is essential.


Assuntos
Aminobutiratos , Glicina , 60658 , Herbicidas , Limite de Detecção , Espectrometria de Massas por Ionização por Electrospray , Espectrometria de Massas em Tandem , Humanos , Glicina/análogos & derivados , Glicina/sangue , Espectrometria de Massas por Ionização por Electrospray/métodos , Aminobutiratos/sangue , Espectrometria de Massas em Tandem/métodos , Herbicidas/sangue , Herbicidas/envenenamento , Reprodutibilidade dos Testes
7.
J Chromatogr A ; 1722: 464866, 2024 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-38581976

RESUMO

The detection of aromatic aldehydes, considered potential genotoxic impurities, holds significant importance during drug development and production. Current analytical methods necessitate complex pre-treatment processes and exhibit insufficient specificity and sensitivity. This study presents the utilization of naphthalenediimide as a pre-column derivatisation reagent to detect aromatic aldehyde impurities in pharmaceuticals via high-performance liquid chromatography (HPLC). We screened a series of derivatisation reagents through density functional theory (DFT) and investigated the phenomenon of photoinduced electron transfer (PET) for both the derivatisation reagents and the resulting products. Optimal experimental conditions for derivatisation were achieved at 40 °C for 60 min. This approach has been successfully applied to detect residual aromatic aldehyde genotoxic impurities in various pharmaceutical preparations, including 4-Nitrobenzaldehyde, 2-Nitrobenzaldehyde, 1,4-Benzodioxane-6-aldehyde, and 5-Hydroxymethylfurfural. The pre-column derivatisation method significantly enhanced detection sensitivity and reduced the limit of detection (LOD), which ranged from 0.002 to 0.008 µg/ml for the analytes, with relative standard deviations < 3 %. The correlation coefficient (R2) >0.998 demonstrated high quality. In chloramphenicol eye drops, the concentration of 4-Nitrobenzaldehyde was measured to be 8.6 µg/mL below the specified concentration, with recoveries ranging from 90.0 % to 119.2 %. In comparison to existing methods, our work simplifies the pretreatment process, enhances the sensitivity and specificity of the analysis, and offers comprehensive insights into impurity detection in pharmaceutical preparations.


Assuntos
Aldeídos , Contaminação de Medicamentos , Imidas , Limite de Detecção , Naftalenos , Cromatografia Líquida de Alta Pressão/métodos , Naftalenos/química , Naftalenos/análise , Aldeídos/análise , Aldeídos/química , Imidas/química , Mutagênicos/análise , Mutagênicos/química , Preparações Farmacêuticas/química , Preparações Farmacêuticas/análise , Benzaldeídos/química , Benzaldeídos/análise
8.
J Chromatogr A ; 1722: 464852, 2024 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-38581974

RESUMO

Xiangdan Injection are commonly used traditional Chinese medicine formulations for the clinical treatment of cardiovascular diseases. However, the trace components of Dalbergia odorifera in Xiangdan Injection pose a challenge for evaluating its quality due to the difficulty of detection. This study proposes a technology combining dispersive liquid-liquid microextraction and back-extraction (DLLME-BE) along with Bar-Form-Diagram (BFD) to address this issue. The proposed combination method involves vortex-mixing tetradecane, which has a lower density than water, with the sample solution to facilitate the transfer of the target components. Subsequently, a new vortex-assisted liquid-liquid extraction step is performed to enrich the components of Dalbergia odorifera in acetonitrile. The sample analysis was performed on HPLC-DAD, and a clear overview of the chemical composition was obtained by integrating spectral and chromatographic information using BFD. The combination of BFD and CRITIC-TOPSIS strategies was used to optimize the process parameters of DLLME-BE. The determined optimal sample pre-treatment process parameters were as follows: 200 µL extraction solvent, 60 s extraction time, 50 µL back-extraction solvent, and 90 s back-extraction time. Based on the above strategy, a total of 29 trace components, including trans-nerolidol, were detected in the Xiangdan Injection. This combination technology provides valuable guidance for the enrichment analysis of trace components in traditional Chinese medicines.


Assuntos
Dalbergia , Medicamentos de Ervas Chinesas , Microextração em Fase Líquida , Microextração em Fase Líquida/métodos , Cromatografia Líquida de Alta Pressão/métodos , Medicamentos de Ervas Chinesas/química , Medicamentos de Ervas Chinesas/análise , Dalbergia/química , Limite de Detecção , Acetonitrilas/química , Reprodutibilidade dos Testes
9.
J Chromatogr A ; 1722: 464872, 2024 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-38581975

RESUMO

LC-MS is an indispensable tool for small molecule analysis in many fields; however, many small molecules require chemical derivatization to improve retention on commonly used reversed-phase columns and increase ionization. Benzoyl chloride (BzCl) derivatization is commonly used for derivatization of primary and secondary amines and phenolic alcohols, though evidence exists that with proper reaction conditions (i.e., specific bases), other hydroxyl groups may be derivatized too. Previous studies have examined BzCl concentration, reaction times, and reaction temperatures for derivatization of amines and phenols for LC-MS analysis; however, use of different bases, base concentration, and extending to conditions to hydroxyl groups for LC-MS analysis has not been well-studied. To address this understudied area and identify reaction conditions for both amino and hydroxyl groups, we performed a systematic study of reaction conditions on multiple classes of potential targets. For selected derivatization methods, detection limits and performance in a variety of biological matrices were assessed. Results highlight the importance of tailoring derivatization methods for a given application as they varied by molecule and/or molecule class. Compared to the standard BzCl method commonly used, alternative methods were identified to better derivatize challenging analytes (glucosamine, choline, cortisol, uridine, cytidine) with detection limits reaching 1100, 9, 38, 170, and 67 nM compared to undetectable, 170, 86, 1000, and 86 nM respectively. Sub-nanomolar detection limits were achieved for norepinephrine with alternative derivatization approaches. Improved derivatization methods for several classes and molecules including nucleosides, steroids, and molecules containing hydroxyl groups were also identified.


Assuntos
Benzoatos , Espectrometria de Massas , Cromatografia Líquida/métodos , Espectrometria de Massas/métodos , Limite de Detecção , Humanos , Aminas/análise , Aminas/química , Colina/análise , Colina/química , Hidrocortisona/análise , Hidrocortisona/química , 60705
10.
Anal Methods ; 16(16): 2505-2512, 2024 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-38584507

RESUMO

Solid phase extraction (SPE) and liquid chromatographic (LC) separation of nucleobases and nucleosides are challenging due to the high hydrophilicity of these compounds. Herein we report a novel on-line SPE-LC-MS/MS method for their quantification after pre-column derivatization with chloroacetaldehyde (CAA). The method proposed is selective and sensitive with limits of detection at the nano-molar level. Analysis of urine and saliva samples by using this method is demonstrated. Adenine, guanine, cytosine, adenosine, guanosine, and cytidine were found in the range from 0.19 (guanosine) to 1.83 µM (cytidine) in urine and from 0.015 (guanosine) to 0.79 µM (adenine) in saliva. Interestingly, methylation of cytidine was found to be significantly different in urine from that in saliva. While 5-hydroxymethylcytidine was detected at a very low level (<0.05 µM) in saliva, it was found to be the most prominent methylated cytidine in urine at a high level of 3.33 µM. Since on-line SPE is deployed, the proposed LC-MS/MS quantitative assay is convenient to carry out and offers good assay accuracy and repeatability.


Assuntos
Nucleosídeos , Saliva , Extração em Fase Sólida , Espectrometria de Massas em Tandem , Espectrometria de Massas em Tandem/métodos , Humanos , Extração em Fase Sólida/métodos , Saliva/química , Cromatografia Líquida/métodos , Nucleosídeos/urina , Nucleosídeos/análise , Limite de Detecção , 60705
11.
ACS Sens ; 9(4): 2000-2009, 2024 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-38584366

RESUMO

This study presents a colorimetric/electrical dual-sensing system (CEDS) for low-power, high-precision, adaptable, and real-time detection of hydrogen sulfide (H2S) gas. The lead acetate/poly(vinyl alcohol) (Pb(Ac)2/PVA) nanofiber film was transferred onto a polyethylene terephthalate (PET) flexible substrate by electrospinning to obtain colorimetric/electrical sensors. The CEDS was constructed to simultaneously record both the visual and electrical response of the sensor, and the improved Manhattan segmentation algorithm and deep neural network (DNN) were used as its intelligent algorithmic aids to achieve quantitative exposure to H2S. By exploring the mechanism of color change and resistance response of the sensor, a dual-sensitivity mechanism explanation model was proposed to verify that the system, as a dual-mode parallel system, can adequately solve the sensor redundancy problem. The results show that the CEDS can achieve a wide detection range of H2S from 0.1-100 ppm and identify the H2S concentration in 4 s at the fastest. The sensor can be stabilized for 180 days with excellent selectivity and a low limit of detection (LOD) to 0.1 ppm of H2S. In addition, the feasibility of the CEDS for measuring H2S levels in underground waterways was validated. This work provides a new method for adaptable, wide range of applications and low-power, high-precision H2S gas detection.


Assuntos
Colorimetria , Aprendizado Profundo , Sulfeto de Hidrogênio , Sulfeto de Hidrogênio/análise , Colorimetria/métodos , Limite de Detecção , Nanofibras/química , Álcool de Polivinil/química , Chumbo/análise , Chumbo/química , Acetatos/química
12.
ACS Sens ; 9(4): 1749-1755, 2024 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-38587118

RESUMO

Aggregation-induced emission (AIE) has offered a promising approach for developing low-background fluorescent methods; however, its applications often suffer from complex probe synthesis and poor biocompatibility. Herein, a novel AIE biosensing method for kanamycin antibiotic assays was developed by utilizing a DNA network nanostructure assembled from an aptamer recognition reaction to capture a large number of tetraphenylethylene fluorogen-labeled signal DNA (DTPE) probes. Due to the excellent hydrophilicity of the oligonucleotides, DTPE exhibited excellent water solubility without obvious background signal emission. Based on an ingenious nucleotide design, an abundance of G-quadruplex blocks neighboring the captured DTPE were formed on the DNA nanostructure. Because of the greatly restricted free motion of DTPE by this unique nanostructure, a strong AIE fluorescence signal response was produced to construct the signal transduction strategy. Together with target recycling and rolling circle amplification-based cascade nucleic acid amplification, this method exhibited a wide linear range from 75 fg mL-1 to 1 ng mL-1 and a detection limit down to 24 fg mL-1. The excellent analytical performance and effective manipulation improvement of the method over previous approaches determine its promising potential for various applications.


Assuntos
Técnicas Biossensoriais , DNA , Quadruplex G , Limite de Detecção , Nanoestruturas , Técnicas Biossensoriais/métodos , Nanoestruturas/química , DNA/química , Corantes Fluorescentes/química , Aptâmeros de Nucleotídeos/química , Espectrometria de Fluorescência , Canamicina/análise , Técnicas de Amplificação de Ácido Nucleico/métodos , Estilbenos/química
13.
ACS Sens ; 9(4): 2183-2193, 2024 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-38588327

RESUMO

Sensitive and selective acetone detection is of great significance in the fields of environmental protection, industrial production, and individual health monitoring from exhaled breath. To achieve this goal, bimetallic Au@Pt core-shell nanospheres (BNSs) functionalized-electrospun ZnFe2O4 nanofibers (ZFO NFs) are prepared in this work. Compared to pure NFs-650 analogue, the ZFO NFs/BNSs-2 sensor exhibits a stronger mean response (3.32 vs 1.84), quicker response/recovery speeds (33 s/28 s vs 54 s/42 s), and lower operating temperature (188 vs 273 °C) toward 0.5 ppm acetone. Note that an experimental detection limit of 30 ppb is achieved, which ranks among the best cases reported thus far. Besides the demonstrated excellent repeatability, humidity-enhanced response, and long-term stability, the selectivity toward acetone is remarkably improved after BNSs functionalization. Through material characterizations and DFT calculations, all these improvements could be attributed to the boosted oxygen vacancies and abundant Schottky junctions between ZFO NFs and BNSs, and the synergistic catalytic effect of BNSs. This work offers an alternative strategy to realize selective subppm acetone under high-humidity conditions catering for the future requirements of noninvasive breath diabetes diagnosis in the field of individual healthcare.


Assuntos
Acetona , Testes Respiratórios , Ouro , Nanofibras , Nanosferas , Platina , Acetona/análise , Acetona/química , Nanofibras/química , Ouro/química , Testes Respiratórios/métodos , Nanosferas/química , Platina/química , Humanos , Limite de Detecção , Oxigênio/química , Técnicas Eletroquímicas/métodos
14.
Anal Methods ; 16(16): 2456-2463, 2024 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-38591267

RESUMO

An elevated level of homocysteine (Hcy) in serum is closely related to the development of various diseases. Therefore, homocysteine has been widely employed as a biomarker in medical diagnosis and the on-site detection of homocysteine is highly desired. In this study, a truncated highly specific aptamer for homocysteine was screened and used to design a lateral flow strip (LFS) for the detection of homocysteine. The aptamer was derived from a previously reported sequence. Based on the result of molecular docking, the original sequence was subjected to truncation, resulting in a reduction of the length from 66 nt to 55 nt. Based on the truncated aptamer, the LFS was designed for the detection of homocysteine. In the presence of homocysteine, the aptamer selectively binds to it, releasing cDNA from the aptamer/cDNA duplex. This allows cDNA to bind to the capture probe immobilized on the T zone of the strip, resulting in a red signal on the T zone from gold nanoparticles (AuNPs). The strip enables the visual detection of homocysteine in 5 min. Quantitative detection can be facilitated with the aid of ImageJ software. In this mode, the linear detection range for homocysteine is within 5-50 µM, with a detection limit of 4.18 µM. The strip has been effectively utilized for the detection of homocysteine in human serum. Consequently, the combination of the truncated aptamer and the strip offers a method that is sensitive, quick, and economical for the on-site detection of homocysteine.


Assuntos
Aptâmeros de Nucleotídeos , Ouro , Homocisteína , Nanopartículas Metálicas , Homocisteína/sangue , Homocisteína/química , Homocisteína/análise , Aptâmeros de Nucleotídeos/química , Humanos , Ouro/química , Nanopartículas Metálicas/química , Limite de Detecção , Técnicas Biossensoriais/métodos , Fitas Reagentes/química , Simulação de Acoplamento Molecular
15.
Anal Methods ; 16(16): 2556-2568, 2024 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-38592494

RESUMO

A novel luminescence-based analytical methodology was established employing a europium(III) complex with 3-allyl-2-hydroxybenzohydrazide (HAZ) as the coordinating ligand for the quantification of gemifloxacin mesylate (GMF) in pharmaceutical preparations and human plasma samples spiked with the compound. The stoichiometry of the europium complex with HAZ was determined via the Job plot and exhibited a metal-to-ligand ratio of 1 : 2. The analytical procedure relies on a rapid and significant enhancement of luminescence by the Eu(AZ)2 complex when it interacts with gemifloxacin mesylate, which allowed for the rapid detection of 96 samples within approximately 2 minutes. The thermodynamic parameters of the complexation of GMF with Eu(AZ)2 were evaluated and showed that the complexation of GMF was spontaneous with a negative ΔG. The binding constant K was 4.27 × 105 L mol-1 and DFT calculations supported GMF binding and the formation of Eu(AZ)2-GMF without further ligand exchange. The calibration graph for the luminescence quantitation of GMF was linear over a wide concentration range of 0.11-16 µg mL-1 (2.26 × 10-7 to 3.30 × 10-5 mol L-1), with a limit of quantification (LOQ) of 110 ng mL-1 (230 nmol L-1) and a detection limit (LOD) of 40 ng mL-1 (82 nmol L-1). The proposed method showed good accuracy with an average recovery of 99% with relative standard deviations of less than 5% in spiking experiments, even in complex pharmaceutical dosage forms such as tablets and in human blood plasma. Herein, the ability of the suppression of the luminescence background by using the long lag times of the lanthanide probe in a time-resolved detection scheme provided reliable and precise results, which suggests its potential for use in further real or patient samples.


Assuntos
Európio , Gemifloxacina , Humanos , Gemifloxacina/química , Gemifloxacina/sangue , Európio/química , Medições Luminescentes/métodos , Limite de Detecção , Complexos de Coordenação/química , Complexos de Coordenação/sangue , Elementos da Série dos Lantanídeos/química , Naftiridinas/sangue , Naftiridinas/química
16.
ACS Sens ; 9(4): 2020-2030, 2024 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-38602529

RESUMO

Lung cancer has become the leading cause of cancer-related deaths globally. However, early detection of lung cancer remains challenging, resulting in poor outcomes for the patients. Herein, we developed an optical biosensor integrating surface-enhanced Raman spectroscopy (SERS) with a catalyzed hairpin assembly (CHA) to detect circular RNA (circRNA) associated with tumor formation and progression (circSATB2). The signals of the Raman reporter were considerably enhanced by generating abundant SERS "hot spots" with a core-shell nanoprobe and 2D SERS substrate with calibration capabilities. This approach enabled the sensitive (limit of detection: 0.766 fM) and reliable quantitative detection of the target circRNA. Further, we used the developed biosensor to detect the circRNA in human serum samples, revealing that patients with lung cancer had higher circRNA concentrations than healthy subjects. Moreover, we characterized the unique circRNA concentration profiles of the early stages (IA and IB) and subtypes (IA1, IA2, and IA3) of lung cancer. These results demonstrate the potential of the proposed optical sensing nanoplatform as a liquid biopsy and prognostic tool for the early screening of lung cancer.


Assuntos
Técnicas Biossensoriais , Neoplasias Pulmonares , RNA Circular , Análise Espectral Raman , Humanos , RNA Circular/sangue , Neoplasias Pulmonares/sangue , Análise Espectral Raman/métodos , Técnicas Biossensoriais/métodos , Detecção Precoce de Câncer/métodos , Limite de Detecção
17.
ACS Sens ; 9(4): 2122-2133, 2024 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-38602840

RESUMO

Terahertz (THz) spectroscopy has impressive capability for label-free biosensing, but its utility in clinical laboratories is rarely reported due to often unsatisfactory detection performances. Here, we fabricated metal-graphene hybrid THz metasurfaces (MSs) for the sensitive and enzyme-free detection of circulating tumor DNA (ctDNA) in pancreatic cancer plasma samples. The feasibility and mechanism of the enhanced effects of a graphene bridge across the MS and amplified by gold nanoparticles (AuNPs) were investigated experimentally and theoretically. The AuNPs serve to boost charge injection in the graphene film and result in producing a remarkable change in the graded transmissivity index to THz radiation of the MS resonators. Assay design utilizes this feature and a cascade hybridization chain reaction initiated on magnetic beads in the presence of target ctDNA to achieve dual signal amplification (chemical and optical). In addition to demonstrating subfemtomolar detection sensitivity and single-nucleotide mismatch selectivity, the proposed method showed remarkable capability to discriminate between pancreatic cancer patients and healthy individuals by recognizing and quantifying targeted ctDNAs. The introduction of graphene to the metasurface produces an improved sensitivity of 2 orders of magnitude for ctDNA detection. This is the first study to report the combined application of graphene and AuNPs in biosensing by THz spectroscopic resonators and provides a combined identification scheme to detect and discriminate different biological analytes, including nucleic acids, proteins, and various biomarkers.


Assuntos
DNA Tumoral Circulante , Ouro , Grafite , Nanopartículas Metálicas , Neoplasias Pancreáticas , Grafite/química , Humanos , Ouro/química , Nanopartículas Metálicas/química , DNA Tumoral Circulante/sangue , DNA Tumoral Circulante/genética , DNA Tumoral Circulante/análise , Neoplasias Pancreáticas/sangue , Neoplasias Pancreáticas/diagnóstico , Técnicas Biossensoriais/métodos , Espectroscopia Terahertz/métodos , Hibridização de Ácido Nucleico , Limite de Detecção
18.
J Chromatogr A ; 1722: 464859, 2024 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-38604056

RESUMO

In this study, molecularly imprinted polymers (MIPs) were prepared for the specific recognition of organophosphorus pesticides and a rapid, efficient and simple method was established for the detection of dimethoate (DIT) in food samples. Fe3O4 magnetic nanoparticles were synthesized by co-precipitation, and Fe3O4/ZIF-8 complexes were prepared by a modified in-situ polymerization method, and then magnetic molecularly imprinted polymers (MMIPs) were prepared and synthetic route was optimized by applying density functional theory (DFT). The morphological characterization showed that the MMIPs were coarse porous spheres with an average particle size of 50 nm. The synthesized materials are highly selective for the organophosphorus pesticide dimethoate with an adsorption capacity of 461.50 mg·g-1 and are effective resistance to matrix effects. A novel method for the determination of DIT in cabbage was developed using the prepared MMIPs in combination with HPLC. The practical results showed that the method can meet the requirements for the determination of DIT in cabbage with recoveries of 85.6-121.1 % and detection limits of 0.033 µg·kg-1.


Assuntos
Brassica , Dimetoato , Limite de Detecção , Polímeros Molecularmente Impressos , Dimetoato/análise , Brassica/química , Polímeros Molecularmente Impressos/química , Adsorção , Cromatografia Líquida de Alta Pressão/métodos , Impressão Molecular/métodos , Nanopartículas de Magnetita/química , Extração em Fase Sólida/métodos , Contaminação de Alimentos/análise
19.
ACS Sens ; 9(4): 1820-1830, 2024 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-38604805

RESUMO

Umami substances play a significant role in the evaluation of food quality, and their synergistic enhancement is of great importance in improving and intensifying food flavors and tastes. Current biosensors available for umami detection still confront challenges in simultaneous quantification of multiple umami substances and umami intensities. In this study, an innovative dual-channel magnetic relaxation switching taste biosensor (D-MRSTB) was developed for the quantitative detection of representative umami substances. The multienzyme signal of D-MRSTB specifically catalyzes the umami substances of interest to generate hydrogen peroxide (H2O2), which is then used to oxidate Fe2+ to Fe3+. Such a valence-state transition of paramagnetic ions was utilized as a magnetic relaxation signaling switch to influence the transverse magnetic relaxation time (T2) within the reaction milieu, thus achieving simultaneous detection of monosodium glutamate (MSG) and inosine 5'-monophosphate (IMP). The biosensor showed good linearity (R2 > 0.99) in the concentration range of 50-1000 and 10-1000 µmol/L, with limits of detection (LOD) of 0.61 and 0.09 µmol/L for MSG and IMP, respectively. Furthermore, the biosensor accurately characterized the synergistic effect of the mixed solution of IMP and MSG, where ΔT2 showed a good linear relationship with the equivalent umami concentration (EUC) of the mixed solution (R2 = 0.998). Moreover, the D-MRSTB successfully achieved the quantitative detection of umami compounds in real samples. This sensing technology provides a powerful tool for achieving the detection of synergistic enhancement among umami compounds and demonstrates its potential for application in the food industry.


Assuntos
Técnicas Biossensoriais , Glutamato de Sódio , Paladar , Técnicas Biossensoriais/métodos , Glutamato de Sódio/química , Inosina Monofosfato/análise , Inosina Monofosfato/química , Limite de Detecção , Análise de Alimentos/métodos , Peróxido de Hidrogênio/química , Peróxido de Hidrogênio/análise , Fenômenos Magnéticos , Aromatizantes/análise , Aromatizantes/química
20.
J Chromatogr A ; 1722: 464895, 2024 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-38608367

RESUMO

Direct sample introduction thermal desorption (TD) coupled to GC-MS was investigated for the analysis of paraffinic hydrocarbons (HCs) from polluted sediments. TD-GC-MS is sometimes used for analysing paraffinic HCs from atmospheric particles but rarely for their direct desorption from sediments. So, the new TD methodology, applied to sediments, required development, optimization and validation. A definitive screening experimental design was performed to discriminate the critical factors on TD efficiency, from model sediments containing various organic matter (OM) amounts. Low molecular weight HCs had extraction behaviours markedly different from high molecular ones (HMW-HCs), but a compromise was found using very few sediment amount (5 mg), high temperature rate (55 °C min-1) and final temperature (350 °C). Linear HCs (n-C10 to n-C40) could be quantified using the matrix-matched calibration method, with very low detection limits (3.8-13.4 ng). The amount of the overall paraffinic alkanes was also determined as a sum of unresolved components between predefined equivalent carbon ranges. The developed solventless methodology was compared to an optimized solvent microwave assisted extraction (MAE). Matrix effects could be higher for TD compared to MAE but it depended on sediment matrix. When matrix effect was strong, particularly on HMW-HCs signal depletion, a dilution with pure non-porous sand was favourable for accurate quantification. The sum of resolved and unresolved HCs gave comparable results between MAE and TD extractions, with an exception of alkanes greater than C30 which were less quantitatively extracted via TD. However, TD-GC-MS was more sensitive than MAE-GC-MS. So TD-GC-MS is useful for analyzing sediments containing a great range of paraffinic HCs (C9-C34) and it has the advantages of being fully automated, with few sample preparation and operator intervention, using very low amounts of solvent, and generating few wastes.


Assuntos
Cromatografia Gasosa-Espectrometria de Massas , Sedimentos Geológicos , Cromatografia Gasosa-Espectrometria de Massas/métodos , Sedimentos Geológicos/química , Sedimentos Geológicos/análise , Limite de Detecção , Hidrocarbonetos Acíclicos/análise , Micro-Ondas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...